Newton validation: 2026-10-23
Newton remains an external compatibility experiment. MyoSuite supports CPU MuJoCo and mjlab; these measurements do not register another backend or establish policy playback or training compatibility.
The tested Newton revision is 4cd047d3d4095c0b19786469f1a5041d049d703e
(upstream PR 4903), based on
12d03b030aeaaf38956e62a76a01760ec36f3747. The environment was Windows,
Python 3.12.10, Warp 1.18.0, MuJoCo and MuJoCo-Warp 3.15.0,
musclemimic_models 1.0.6, and an NVIDIA RTX 4050 Laptop GPU with 6 GB and
driver 610.60. The upstream branch is unreleased; reproducing these results with
the next released Newton remains pending in
MyoSuite issue 563.
Upstream status, 2026-10-31
PR 4903 has been split. Newton PR 5029
(joint equality endpoints and partial polycoef) and
Newton PR 5030
(partial vector attributes) carry the import fixes onto Newton main
2e20d82d. With both, the conversion probe again converts all twelve cases
with every muscle and length range and the static force errors listed below.
Body masses of the elbow and bimanual models, the integrator and the sensors
still differ: the mesh inertia, compiler bound, option, geom gap, multi-CCD and
CPU margin changes of PR 4903 alter Newton defaults and are not part of those
two PRs. The trajectory tables below were measured with all of PR 4903 applied.
Conversion and names
All twelve authored/normalized cases import with their meshes and convert. Body, joint, DoF, tendon, wrap, equality and sensor counts, mass and the measured solver options agree. Every muscle is retained and all length ranges agree at the configured tolerance (the largest absolute range difference is 1.49e-8 m). Authored inputs preserve the scene meshes; the normalized diagnostic still removes binary mesh geoms, as described in Backend parity.
The strict conversion command still exits with status 1. Raw body, joint and site
names change, and static muscle forces exceed the narrow default bounds
(rtol=1e-6, atol=1e-8). Maximum authored static force errors are
0.000249 N (elbow), 0.005292 N (hand), 0.009347 N (arm), 0.002569 N (leg),
0.004643 N (full body), and 0.002121 N (bimanual). These differences are reported
separately from structural preservation.
The numerical harness records complete one-to-one source-to-converted identity maps for bodies, joints and sites in all six models. Hierarchical namespace prefixes and generated joint/shape suffixes explain the changed names; the scalar joint identities are recovered through per-DoF labels or, where Newton merges a body’s joints without them, through the merged joint’s name and DoF order. A stable public mapping API and exact-name round trips are tracked in Newton issue 4904. Raw names are not counted as preserved by the strict probe.
Matched trajectories
.github/newton_probe/newton_dynamics_probe.py compares the original authored native CPU
model with Newton’s converted CPU MuJoCo or CUDA MuJoCo-Warp solver. It uses
the default pose and a deterministic small scalar-joint perturbation, identical
sinusoidal muscle controls, and 128 steps at the authored timestep and integrator.
The bounds were fixed before these runs: qpos rtol=1e-4, atol=1e-4
(radians/metres), and muscle force rtol=1e-3, atol=0.05 N. The force bounds
reject a 10% muscle force/scale mutation in every model and pose. The qpos bounds
reject the earlier incorrect leg contact-gap import by more than three orders of
magnitude.
Each row gives the largest absolute errors over both poses and all steps. Pass/fail uses the component-wise relative and absolute bounds, rather than only the maxima shown here. Contact capacity is 2048 and constraint capacity 8192, with Newton’s strict capacity checking enabled.
Model |
Result |
Max qpos error |
Max force error (N) |
|---|---|---|---|
Elbow |
Pass |
9.26e-7 |
0.000355 |
Hand |
Pass |
2.58e-5 |
0.003127 |
Arm |
Pass |
3.23e-6 |
0.013120 |
Leg |
Pass |
2.04e-6 |
0.013303 |
Full body |
Fail |
3.42e-4 |
3.073153 |
Bimanual |
Pass |
1.02e-5 |
0.002993 |
The full-body CPU comparison first exceeds qpos bounds at step 40 in both poses. Its force peaks occur in the soleus muscles. The precise remaining cause has not been established; Newton’s float32 model storage is a plausible source of round-trip perturbations, rather than evidence of exact CPU equivalence.
Model |
Result |
Max qpos error |
Max force error (N) |
|---|---|---|---|
Elbow |
Pass |
3.60e-6 |
0.000590 |
Hand |
Fail |
0.001325 |
0.359166 |
Arm |
Fail |
0.004090 |
4.898774 |
Leg |
Fail |
0.018801 |
588.226064 |
Full body |
Fail |
0.013615 |
111.197886 |
Bimanual |
Fail |
0.002998 |
69.780513 |
The CUDA solver also warns that it zeros some authored geom margins for its native-CCD compatibility path. This changes contact semantics and is retained in the reports. No bounds were relaxed to make these failures pass.
Independent contact and solver checks
An omitted MJCF geom gap previously inherited Newton’s speculative gap of 0.1 m. For MyoLeg this created 115 initial contacts where native MuJoCo had zero. PR 4903 preserves the source gap of zero. An independent lowered-root audit now finds identical contact-pair multisets at 16, 53 and 72 contacts, distance errors below 9.49e-8 m, and matching collision properties for all 56 named geoms. The leg CPU rollout above reaches 16-18 contacts and passes the fixed bounds.
Directly transferring the same authored model to MuJoCo-Warp, without importing Newton, reproduces wrist trajectory drift for hand, arm and bimanual models. The matched control with contacts disabled still fails; GPU buffer overflow counters remain zero. The direct leg comparison passes with contacts disabled and diverges after landing with contacts enabled. These observations separate solver/contact behavior from Newton import errors without assigning an unproven cause. Wrap sensitivity and run-to-run force-peak variation remain under investigation in MuJoCo-Warp issue 1835.
Reproduce and download
Use a separate environment for Newton and install the exact upstream revision:
uv venv --python 3.12 .venv-newton
uv pip install --python .venv-newton "newton[sim] @ git+https://github.com/M-Colley/newton.git@4cd047d3d4095c0b19786469f1a5041d049d703e" "musclemimic_models==1.0.6" -e .
.venv-newton/bin/python .github/newton_probe/newton_compat_probe.py --strict --out newton_conversion
.venv-newton/bin/python .github/newton_probe/newton_dynamics_probe.py --engine cpu --device cpu --poses 2 --steps 128 --newton-revision 4cd047d3d4095c0b19786469f1a5041d049d703e --out newton_cpu
.venv-newton/bin/python .github/newton_probe/newton_dynamics_probe.py --engine warp --device cuda:0 --poses 2 --steps 128 --newton-revision 4cd047d3d4095c0b19786469f1a5041d049d703e --out newton_cuda
On Windows use .venv-newton/Scripts/python.exe. The numerical harness writes
its report incrementally and exits with status 1 when any case fails the bounds.
It is a manual diagnostic; the release/manual conversion workflow remains
informational and does not run these GPU trajectories.
The reports themselves are not stored in the repository. The commands above
regenerate every table on this page, with dependency metadata and the source
revision in each JSON report, and the release workflow
(.github/workflows/newton-probe.yml) uploads its conversion report as the
newton-probe-<version> run artifact.
The focused upstream suite ran 118 tests with 6 optional-USD skips; all executed tests and pre-commit hooks passed. New regressions fail on the unmodified baseline. Upstream hosted checks require maintainer approval for this fork. Released-version validation, broader GPU equivalence, timing and real policy playback remain open acceptance criteria in issue 563.